    Interface signals are used for communicating with (i.e., receiving input and sending output, as binary signals, from/to) external devices, connected to the CNC machine. This issue is discussed in more detail in Chap. Here, only a broad overview is given, with-out going into the finer details, so, certain things may not be very. USB Digital Input/Output Device. LabJack produces low cost, high quality, USB data acquisition and control products with many digital inputs and outputs. The LJM Library is a set of functions used to easily communicate with several of our devices using a simple Modbus over USB interface (as well as Modbus TCP/UDP when applicable). 7300 Series 90-30 SSI/LDT Interface Module Supplying absolute position and velocity data to your programmable controller, the single slot 7351 Linear Displacement Transducer interface module is a direct connection between Balluff and MTS linear displacement transducers (LDTs) and the GE 90-30 PLC.

    I have a Fanuc R-30iA robot controller. I am using a GE quick panel for a HMI / operators panel. How do I define the robot I/O I would like to read and write in the quick panel.

    It seems like you define the signals as variables in the quickpanel. To start simple, I would like to put a program start and program stop button on the screen that would turn green based on if the program is running or not. It seems like you would use color animation for this and declare a input as a variable.

    Is this correct and how do you tie the variable to the robot IO? I have done this and it works great. We currently have many Fanuc Robots and Red Lion G3 HMI's communicating via Ethernet. First you have to make sure you have the HMI Option on your Robot.From the Arctool Manual:This manual is meant to be a supplement reference manual to the HMI Device Setupand Operations Manual.

    This manual details the addressing and setup of systemvariables for the R-J3iB Controller.The R-J3iB controller communicates with the HMI device by using the R-J3iBController as a GE Fanuc Series 90 PLC. Various data of the R-J3iB corresponds tothe address of Series 90 PLC.

    The HMI device accesses this data by accessing thecorresponding PLC address. This communication uses the SNPX communicationProtocol.2. Accessing I/O ports (%I,%Q,%M%AI,%AQ)The R-J3iB DI1 can be accessed from HMI device as%Q1.

    For the PLC Access Driver within GE Machine Edition software, I used the GE TCPIP under View Native Driver/ GE Intelligent Platforms.I needed SNPX for additional functionality of the HMI such as displaying alarm history and reading registers and robot status.Assignments to robot registers, position registers, current posisiton, alarm history, program execution status andsystem variables need to be set up through the system variable $SNPXASGIt seems in the fanuc controller, SNPX is not a physical interface but rather a software interface. What does this have to do with the OP of comms between a robot and a QuickPanel?Hi friend.I'm using GE's Proficy software and trying to read some internal registers of Fanuc RJ3iB. Via the GE TCPIP ethernet drive.Please, could you please exemplify how I do this.

    I checked and the Robot has the optional SNPX. But.i don't know.

    Why do I need the optional SNPx, if I'm going to use TCPIP?. How is mapped the internal memory registers in RJ3ib? That is, How the software Proficy sees these records.thank you so mucheaglegoodProficy Machine Edition software is typically used to write PLC/PAC programs and QuickPanel or PC based HMI programs. As such they work well with many communication protocols.

    Fanuc Digital Outputs Over Crma Interfaces

    Which of these are you writing with PME? GE SNPx and SNP are serial protocols The default Ethernet protocol for GE products is GE SRTP, does your robot have it installed? You may also verify if the robot has EGD or Modbus TCP/IP. My knowledge of Fanuc robots is limited. I know they are yellow. I know they share a lot of technology with Fanuc CNCs.

    Fanuc digital outputs over crma interface download

    Fanuc Digital Outputs Over Crma Interface Program

    I know their manuals are hard to follow.First you have to make sure you have the HMI Option on your Robot.Does your robot have the HMI option?In your Proficy View PC target, you will need to add the GETCPIP driver. By default it will be given the name 'Device1'. You can rename it if you want. When you create a variable in the View target you must define it as 'PLC Access' and specify that it is to use Device1.

    When you do that you must enter a PLC address for the variable. GE Series 90 memory designations are%I for discrete inputs,%Q for discrete outputs.%M for discrete internal memory bits,%AI for analog inputs.%AQ for analog outputs and%R for 16-bit register memory. 32-bit variables will use two consecutive%R addresses. What’s up guy? Thank you for this. I am currently connecting a Schneider HMI to a Fanuc R-30iB over Ethernet, and I thought I was going to have to use flags for all the UOPs. Accessing I/O ports (%I,%Q,%M%AI,%AQ)The R-J3iB DI1 can be accessed from HMI device as%Q1.